Customization: | Available |
---|---|
After-sales Service: | One Year |
Warranty: | One Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electromagnetic
Flowmeter for smallest flow rates with genuine loop-powered technology.
Dedicated to the measurement of the smallest flow quantities.
Flexible installation concept - numerous process connections. Energy‐saving flow measurement - no pressure loss due to cross section constriction. Maintenance‐free - no moving parts.
Liner made of PFA. Sensor housing made of stainless steel. Various electrode materials available.
Convenient device wiring - separate connection compartment. Safe operation - no need to open the device due to display with touch control, background lighting. Integrated verification - Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
DN 2 to 25 (¹⁄12 to 1")
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum
Volume flow, mass flow
Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min)
PN 40, Class 150, 20K
-20 to +150 °C (-4 to +302 °F)
-40 to +60 °C (-40 to +140 °F)
1.4301 (304), corrosion resistant
AlSi10Mg, coated
IP66/67, type 4X enclosure
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
4‐20 mA HART (passive)
Pulse/frequency/switch output (passive)
None
HART, PROFIBUS PA, FOUNDATION Fieldbus
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN, UK Ex
CE, C-Tick
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 - Section 7.1.5.2 a (TÜV SÜD attestation)
CRN
3.1 material