Customization: | Available |
---|---|
After-sales Service: | One Year |
Warranty: | One Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electromagnetic
Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter.
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
Dedicated to the measurement of industrial or municipal water and wastewater .
Flexible engineering - sensor with fixed or lap-joint process connections. Long-term operation - robust and completely welded sensor. Improved plant availability - sensor compliant with industry-specific requirements.
International drinking water approvals.
Full access to process and diagnostic information - numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety - freely configurable I/O functionality. Integrated verification - Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
DN 25 to 3000(1 to 120")
Liner: Polyurethane; Hard rubber, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Volume flow, conductivity, mass flow
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
PN 40, Class 300, 20K
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: -20 to +50 °C (-4 to +122 °F)
Liner material PTFE: -20 to +90 °C (-4 to +194 °F)
Flange material carbon steel: -10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: -40 to +60 °C (-40 to +140 °F)
DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 25 to 2400 (1 to 90"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Status input 4-20 mA input
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
CE, C-tick, EAC marking
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 - Section 7.1.5.2 a (TÜV SÜD attestation)
LR approval, DNV approval, ABS approval, BV approval
CRN, PED
3.1 material
ACS, KTW/W270, NSF 61, WRAS BS 6920