Indumax CLS50D is a digital inductive conductivity sensor for standard, hazardous and high-temperature applications. Benefit from high chemical resistance and long durability thanks to robust materials (PFA, PEEK). Moreover, it is insensitive to soiling and performs reliable and repeatable even in harsh and aggressive media. Thanks to Memosens, CLS50D combines maximum process and data integrity with simple operation. It resists corrosion and moisture and facilitates predictive maintenance.
High durability and chemical resistance even under harsh conditions
Dirt-repellent materials and large sensor opening avoid soiling
Wide temperature range and highly resistant materials make the sensor suitable for virtual any application
Reliable values thanks to active connection monitoring
Easy wiring over long distances without impact on the measurement accuracy
Logging of sensor-specific data for easy traceability
Approved for hazardous area use
Indumax CLS50D measures toroidal conductivity in:
Chemicals:
- Concentration measurement of acids and bases
- Quality monitoring of chemical products in tanks and pipes
Food & Beverages:
- Phase separation of product/product mixtures in pipe systems
Life Sciences:
- Phase separation of product/product mixtures in pipe systems
Wastewater industry:
- Inlet monitoring
With its international explosion protection approvals, such as ATEX, FM, CSA, NEPSI, it is suitable for hazardous areas.
Inductive
Chemical industry, process
Analog or digital, inductive conductivity sensor for standard, Ex and
high-temperature applications
2µS/cm to 2000 mS/cm
Inductive conductivity measurement
No direct contact with the media because of the sensor coating made of highly resistant material
PEEK or PFA
Electrode:
Outside diameter: 47.5 mm (1.87 inch)
Inside diameter: 15 mm (0.59 inch)
Inside diameter (PEEK version): 15.5 mm (0.61 inch)
PEEK: max. 125°C (max. 260 °F)
PFA: max. 110°C (max. 230 °F)
PEEK: max. 21 bar (max. 304.5 psi)
PFA: max. 17 bar (max. 246.5 psi)
Integrated Pt1000
ATEX, IECEx, NEPSI, FM, CSA, TIIS, EAC
Process connection: NPT1", DN50, AINSI, JIScable: fixed cable connection
IP 68 / NEMA type 6
Calibration certification of the cell constant